LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Hemoglobin A1c and Fructosamine Evaluated in Patients with Type 2 Diabetes Receiving Peritoneal Dialysis Using Long-Term Continuous Glucose Monitoring.

Photo by mykjohnson from unsplash

INTRODUCTION Shortened erythrocyte life span and erythropoietin-stimulating agents may affect hemoglobin A1c (HbA1c) levels in patients receiving peritoneal dialysis (PD). We compared HbA1c with interstitial glucose measured by continuous glucose… Click to show full abstract

INTRODUCTION Shortened erythrocyte life span and erythropoietin-stimulating agents may affect hemoglobin A1c (HbA1c) levels in patients receiving peritoneal dialysis (PD). We compared HbA1c with interstitial glucose measured by continuous glucose monitoring (CGM) in patients with type 2 diabetes receiving PD. METHODS Fourteen days of CGM (Ipro2, Medtronic) were performed in 23 patients with type 2 diabetes receiving PD and in 23 controls with type 2 diabetes and an estimated glomerular filtration rate over 60 mL/min/1.73 m2. Patients were matched on gender and age (±5 years). HbA1c (mmol/mol), its derived estimate of mean plasma glucose (eMPGA1c) (mmol/L), and fructosamine (µmol/L) were measured at the end of the CGM period and compared with the mean sensor glucose (mmol/L) from CGM. RESULTS In the PD group, mean sensor glucose was 0.98 (95% con-fidence interval (CI): 0.43-1.54) mmol/L higher than the eMPGA1c compared with the control group (p = 0.002) where glucose levels were nearly identical (-0.05 (95% CI: -0.35-0.25) mmol/L). A significant association was found between fructosamine and mean sensor glucose using linear regression with no difference between slopes (p = 0.89) or y-intercepts (p = 0.28). DISCUSSION/CONCLUSION HbA1c underestimates mean plasma glucose levels in patients with type 2 diabetes receiving PD. However, the clinical significance of this finding is undetermined. Fructosamine seems to more accurately reflect glycemic status. CGM or fructosamine could complement HbA1c to increase the accuracy of glycemic monitoring in the PD population.

Keywords: diabetes receiving; patients type; hemoglobin a1c; type diabetes; monitoring; fructosamine

Journal Title: Nephron
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.