LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Validation of a Protocol for Continuous Hemodiafiltration with Regional Citrate Anticoagulation with Omni®

Photo by jsrm99 from unsplash

Introduction: Omni® (B Braun, Melsungen, Germany) is able to run continuous renal replacement therapy (CRRT) in continuous veno-venous hemofiltration (CVVH), hemodialysis (CVVHD), and hemodiafiltration (CVVHDF) modes. However, to date, there… Click to show full abstract

Introduction: Omni® (B Braun, Melsungen, Germany) is able to run continuous renal replacement therapy (CRRT) in continuous veno-venous hemofiltration (CVVH), hemodialysis (CVVHD), and hemodiafiltration (CVVHDF) modes. However, to date, there is no validated protocol to guide the use of Omni® in CVVHDF mode with regional citrate anticoagulation (RCA). Methods: We designed a protocol for CVVHDF-RCA tailored for Omni®. This protocol was tested in patients included in an observational study conducted in our center between January and March 2021. For all study patients, we collected baseline characteristics, laboratory results, CRRT circuit lifespan as well as plasma and effluent samples at 12, 24, 48, and 72 h of CRRT circuit initiation. At each study time point, we computed urea, creatinine, and β2-microglobulin clearance as well as effluent/blood ratios. Data from circuits in CVVHDF-RCA mode are compared with those in standard therapy (CVVHD-RCA) with the same device. Results: We analyzed ten circuits (5 patients) in CVVHDF-RCA mode and 32 (13 patients) in CVVHD-RCA mode. No adverse events related to the therapy were observed. In CVVHDF-RCA mode, median circuit running time was 68 (IQR 8.1) hours versus 46 (IQR 9.0) in CVVHD mode, p = 0.053. Therapy adaptations (dialysate rate and/or blood flow) were required in one (10%) circuit (15.6% in CVVHD mode, p = 0.56). Compared to CVVHD, CVVHDF was able to achieve similar clearance and effluent/blood ratio for urea, creatinine, and β2-microglobulin across the entire duration of circuit lifetime. Conclusion: The proposed protocol for CVVHDF-RCA for Omni® was associated with similar circuit lifetime, number of required adaptations and clearances to standard CVVHD-RCA. It appears to be safe and feasible.

Keywords: circuit; rca; cvvhdf rca; cvvhd; protocol; mode

Journal Title: Blood Purification
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.