Analytical bias of automated immunoassays for six serum steroid hormones assessed by LC-MS/MS

Photo by nci from unsplash

Introduction There is a growing amount of evidence showing the significant analytical bias of steroid hormone immunoassays, but large number of available immunoassays makes conduction of a single comprehensive study… Click to show full abstract

Introduction There is a growing amount of evidence showing the significant analytical bias of steroid hormone immunoassays, but large number of available immunoassays makes conduction of a single comprehensive study of this issue hardly feasible. Aim of this study was to assess the analytical bias of six heterogeneous immunoassays for serum aldosterone, cortisol, dehydroepiandrosterone sulphate (DHEAS), testosterone, 17-hydroxyprogesterone (OHP) and progesterone using the liquid chromatography coupled to the tandem mass spectrometry (LC-MS/MS). Materials and methods This method comparison study included 49 serum samples. Testosterone, DHEAS, progesterone and cortisol immunoassays were performed on the Abbott Architect i2000SR or Alinity i analysers (Abbott Diagnostics, Chicago, USA). DiaSorin’s Liaison (DiaSorin, Saluggia, Italy) and DIAsource’s ETI-Max 3000 analysers (DIAsource ImmunoAssays, Louvain-La-Neuve, Belgium) were chosen for aldosterone and OHP immunoassay testing, respectively. All immunoassays were evaluated against the LC-MS/MS assay relying on the commercial kit (Chromsystems, Gräfelfing, Germany) and LCMS-8050 analyser (Shimadzu, Kyoto, Japan). Analytical biases were calculated and method comparison was conducted using weighted Deming regression analysis. Results Depending on the analyte and specific immunoassay, mean relative biases ranged from -31 to + 137%. Except for the cortisol, immunoassays were positively biased. For none of the selected steroids slope and intercept 95% confidence intervals simultaneously contained 0 and 1, respectively. Conclusions Evaluated immunoassays failed to satisfy requirements for methods’ comparability and produced significant analytical biases in respect to the LC-MS/MS assay, especially at low concentrations.

Keywords: bias automated; immunoassays six; analytical bias; six serum; bias; automated immunoassays

Journal Title: Biochemia Medica
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.