LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Selectivity Quantification with the Fluorescent Quantitative Model-Assisted Semi-Selective Probe (Carbon Dots): Accurate Determination of Chlortetracycline in Aqueous Environments with Interference.

Photo by thinkmagically from unsplash

Probes such as carbon dots (C-dots) have extensive and important applications in the quantitative analysis of complex biological and environmental systems. However, the development of probes is often hindered by… Click to show full abstract

Probes such as carbon dots (C-dots) have extensive and important applications in the quantitative analysis of complex biological and environmental systems. However, the development of probes is often hindered by incomplete selectivity, i.e., a probe that responds to one substance is also prone to respond to coexisting structurally similar substances. Therefore, the above dilemma often leads to be developed as semi-selective probes, so that the development of probes is abandoned halfway. This work shows how a semi-selective probe can enhance selectivity by combining a proper multivariate calibration model. Primarily, we developed a semi-selective fluorescent probe that responded to tetracyclines (TCs) with discarded tobacco leaves. Then, we introduced the multivariate quantitative fluorescence model (QFM) to enhance its selectivity and solve the problem of fluorescence spectral shift. For the determination of chlortetracycline (CTC) with this semi-selective C-dots probe in mineral and lake water samples and compared to the traditional quantitative model, the introduced QFM resulted in an average relative predictive error (ARPE) in mineral water spiked samples decreased from 57.1 to 5.6%, which reduced the ARPE in the lake water spiked samples from 18.1 to 4.7%. The above results show that the QFM-assisted semi-selective probe C-dots strategy (QFMC-dots) can enhance selectivity, and QFMC-dots achieved high-selective and accurate determination of CTC in interfering mineral and lake water samples, with the limit of detection and limit of quantitation of 0.55 and 1.66 μM, respectively. The proposed strategy of enhancing selectivity by introducing a proper multivariate calibration model can reduce the difficulty and increase success rate of developing probes, which can be expected to provide an interesting alternative for the development of probes, especially when encountering semi-selective problems.

Keywords: determination; model; semi selective; selectivity; selective probe

Journal Title: Applied spectroscopy
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.