LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Multi-echo Dixon and breath-hold T2-corrected multi-echo single-voxel MRS for quantifying hepatic iron overload in rabbits.

Photo from wikipedia

BACKGROUND Three-dimensional (3D) multi-echo-Dixon (ME-Dixon) and breath-hold T2-corrected multi-echo single-voxel MR spectroscopy (HISTO) can simultaneously quantify liver fat and liver iron. However, their diagnostic efficacy and application scope for quantitative… Click to show full abstract

BACKGROUND Three-dimensional (3D) multi-echo-Dixon (ME-Dixon) and breath-hold T2-corrected multi-echo single-voxel MR spectroscopy (HISTO) can simultaneously quantify liver fat and liver iron. However, their diagnostic efficacy and application scope for quantitative iron in co-existing fatty liver have not been adequately evaluated. PURPOSE To evaluate the accuracy of ME-Dixon and HISTO for quantitative analysis of hepatic iron in rabbits with iron deposition and fatty liver using liver-iron concentration (LIC) as a reference standard. MATERIAL AND METHODS ME-Dixon, HISTO, and conventional two-dimensional multi-echo gradient echo (GRE) sequences were performed on 42 rabbits. The following parameters were calculated: R2* from ME-Dixon and GRE; proton density fat fraction (PDFF) from the ME-Dixon, HISTO (normal TE range), and HISTO-H (extended TE range); and R2_water from HISTO and HISTO-H. The LIC and liver-fat concentration (LFC) were measured through chemical analysis, and their relationship with the MRI parameters were assessed. Receiver operating characteristic (ROC) curves and the area under the curve (AUC) were used to evaluate the diagnostic efficiency. RESULTS LIC was significantly correlated with R2_HISTO-H, R2*_Dixon, and R2*_GRE (r = 0.858, 0.910, 0.931, respectively; P < 0.001) and weakly with R2_HISTO (r = 0.424; P = 0.008). A strong correlation was also observed between the LFC and PDFF obtained from HISTO, HISTO-H, and ME-Dixon (r = 0.776, 0.811, 0.888, respectively; P < 0.001). ME-Dixon showed the best performance with moderate iron overload (AUC = 0.983). CONCLUSION 3D ME-Dixon is useful for quantifying the LIC, especially with co-existing fatty liver. Its diagnostic performance is also superior to that of the HISTO sequence.

Keywords: multi echo; histo; iron; dixon

Journal Title: Acta radiologica
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.