LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Use of ABC/2 method for rapidly estimating the target mismatch on computed tomography perfusion imaging in patients with acute ischemic stroke.

Photo from wikipedia

BACKGROUND Target mismatch (ischemic core, mismatch volume and mismatch ratio) in patients with acute ischemic stroke (AIS) highly relies on the automated perfusion analysis software. PURPOSE To evaluate the feasibility… Click to show full abstract

BACKGROUND Target mismatch (ischemic core, mismatch volume and mismatch ratio) in patients with acute ischemic stroke (AIS) highly relies on the automated perfusion analysis software. PURPOSE To evaluate the feasibility and accuracy of using the ABC/2 method to rapidly estimate the target mismatch on computed tomography perfusion (CTP) imaging in patients with AIS, using RAPID results as a reference. MATERIAL AND METHODS In total, 243 patients with anterior circulation AIS who underwent CTP imaging were retrospectively reviewed. Target mismatch associated perfusion parameters were derived from RAPID results and calculated using the ABC/2 method. Paired t-test was used to assess the difference of volumetric parameters between the two methods. The ability of using the ABC/2 method to predict the important cutoff volumetric metrics was also evaluated. RESULT There was no significant difference in the volumes of ischemic core (P = 0.068), ischemic area (P = 0.209), and mismatch volume (P = 0.518) between ABC/2 and RAPID. Using RAPID results as reference, the ABC/2 method showed high accuracy for predicting perfusion parameters (70 mL and 90 mL: sensitivity=98.5% and 98.5%, specificity=100% and 100%, positive predictive value [PPV]=100% and 100%, negative predictive value [NPV]=93.8% and 92.9%; 10 mL and 15mL: sensitivity=99.6% and 99.5%, specificity=55.6% and 50.0%, PPV=96.6% and 94.8%, NPV=90.9% and 92.3%; 1.2 and 1.8: sensitivity=99.6% and 94.8%, specificity=75.0% and 96.9%, PPV=98.7% and 99.5%, NPV=90.0% and 73.8%). CONCLUSION The ABC/2 method may be a feasible alternative to RAPID for estimation of target mismatch parameters on CTP in patients with AIS.

Keywords: target mismatch; mismatch; abc method; perfusion

Journal Title: Acta radiologica
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.