LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Efficacy and Safety of Cisatracurium Compared to Vecuronium for Neuromuscular Blockade in Acute Respiratory Distress Syndrome

Photo from wikipedia

Purpose Previous studies analyzing neuromuscular blocking agents (NMBAs) in acute respiratory distress syndrome (ARDS) have evaluated the benefit of cisatracurium with conflicting results, and data evaluating other NMBAs remains limited.… Click to show full abstract

Purpose Previous studies analyzing neuromuscular blocking agents (NMBAs) in acute respiratory distress syndrome (ARDS) have evaluated the benefit of cisatracurium with conflicting results, and data evaluating other NMBAs remains limited. The objective of this study was to compare the efficacy and safety of cisatracurium to vecuronium in ARDS. Materials and methods A single-center, retrospective, propensity matched review of patients who received cisatracurium or vecuronium continuous infusions between October 1, 2017 and June 30, 2020 for ARDS was conducted. The primary endpoint was duration of mechanical ventilation. Secondary endpoints included change in PaO2/FiO2 ratio at 48 h, intensive care unit (ICU) and hospital mortality, and ICU and hospital length of stay (LOS). Safety endpoints included newly developed myopathy, presence of bradycardia or hypotension, and newly developed barotrauma or volutrauma. Results Twenty-nine patients were included in each group. There was no statistically significant difference in the primary endpoint of ventilator days between cisatracurium and vecuronium groups (mean 15.9 vs. 20.5 days respectively; p = .2). No statistically significant differences were found in secondary endpoints of ICU mortality (51.7% vs. 51.7%) or length of stay (18.7 vs. 23.9 days, p = .19), hospital mortality (51.7% vs. 55.2%, p = .79) or length of stay (22 vs. 30.6 days, p = .08), or mean change in PaO2/FiO2 (29.8 vs. 36.6; p = .74). Statistically significant differences were not observed in safety endpoints of myopathy (37.9% vs. 37.9%), barotrauma or volutrauma (13.8% vs. 3.5%; p = .16), bradycardia (31% vs. 13.8%; p = .12), or hypotension (96.6% vs. 82.8%; p = .08) Conclusions No significant differences were seen in efficacy or safety endpoints between cisatracurium or vecuronium groups, suggesting that vecuronium may be a safe alternative agent for neuromuscular blockade in ARDS. Results of this analysis warrant confirmation in a larger, randomized study.

Keywords: safety; acute respiratory; vecuronium; efficacy safety; cisatracurium

Journal Title: Journal of Intensive Care Medicine
Year Published: 2022