The clocking position of the vaned diffuser, the circumferential position of the vaned diffuser relative to the volute, has a certain effect on the performance of the centrifugal pump. Therefore,… Click to show full abstract
The clocking position of the vaned diffuser, the circumferential position of the vaned diffuser relative to the volute, has a certain effect on the performance of the centrifugal pump. Therefore, this paper studies the guide vane centrifugal pump from the aspects of pressure pulsation, hydraulic performance, and energy loss. The maximum difference in efficiency is 3.4% under the design flow rate, and the maximum difference in the head coefficient is 4.7%. The hydraulic performance and pressure pulsation present different trends with the increase of the vaned diffuser clock angle. When the hydraulic performance and pressure pulsation are relatively good, the circumferential distance between the tongue and the upstream vaned diffuser blade is 3/4 of the diffuser flow path. In addition, the recommended vaned diffuser installation location may also be suitable for centrifugal pumps of similar construction. The energy loss was visualized using the theory of entropy production. The distributions of energy loss and flow field indicate that the energy loss of impeller and vaned diffuser changes little. The change of the vortex in the tongue and outlet area will cause a significant change in the energy loss of the volute, which is the main reason that the hydraulic performance of the centrifugal pump is affected by the clocking position of the vaned diffuser.
               