LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Interlaboratory comparison of heavy metal testing in animal diagnostic specimens and feed using inductively coupled plasma–mass spectrometry

Photo from wikipedia

We compared inductively coupled plasma–mass spectrometry (ICP-MS) test results for the analysis of heavy metals (As, Ba, Cd, Hg, Pb, and Se) in pet foods and routine veterinary diagnostic specimens… Click to show full abstract

We compared inductively coupled plasma–mass spectrometry (ICP-MS) test results for the analysis of heavy metals (As, Ba, Cd, Hg, Pb, and Se) in pet foods and routine veterinary diagnostic specimens using intralaboratory and interlaboratory comparisons. Four laboratories, 1 principal laboratory and 3 collaborating laboratories, conducted instrument comparison (limit of detection [LOD], limit of quantification [LOQ], and linear dynamic range [LDR] on 24 data sets), in-house method comparison (accuracy and precision on 120 data sets), and interlaboratory comparison (reproducibility on 528 data sets using Horwitz equation analysis). Matrices tested included 2 types of pet food jerky treats (chicken and sweet potato), bovine blood, and bovine liver and kidney. The instrument comparison study confirmed that ICP-MS provided the sensitivity necessary for the analysis of all heavy metals tested at concentrations below the level of concern for routine diagnostic testing. The “in-house” method comparison samples, spiked at low (0.04 µg/g), medium (0.4 µg/g), and high (8.0 µg/g; note: the high validation level spike for mercury was 2 µg/g) concentration levels, indicated that ICP-MS can meet U.S. FDA acceptance criteria for both accuracy (90–105% recovery) and precision (< 6% coefficient of variation). The interlaboratory comparison studies showed that ICP-MS is a reproducible method for the analysis of heavy metals (HorRat value of 0.5–2.0) except for mercury in one laboratory, which used a different sample preparation method (open block rather than microwave digestion). Overall, our study showed that ICP-MS is a reproducible method for the analysis of heavy metals in spite of minor differences in methodology.

Keywords: plasma mass; coupled plasma; method; interlaboratory comparison; inductively coupled; comparison

Journal Title: Journal of Veterinary Diagnostic Investigation
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.