LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Biomechanical evaluation of three fixation methods in a feline transverse patella fracture model

Photo from wikipedia

Objectives This study aimed to compare the biomechanical properties of three stabilisation techniques in feline patella transverse fractures and select the strongest method with potentially minimal complications. Methods Patella fracture… Click to show full abstract

Objectives This study aimed to compare the biomechanical properties of three stabilisation techniques in feline patella transverse fractures and select the strongest method with potentially minimal complications. Methods Patella fracture was simulated in 27 feline cadaveric pelvic limbs (mean weight of the cadavers 3.78 kg), and the limbs were randomly grouped to be stabilised with one of the three stabilisation methods. The modified tension band wiring technique with a single Kirschner wire (0.9 mm) and figure-of-eight wiring (20 G) was applied to group 1 (n = 9). Group 2 (n = 9) was stabilised with a combination of circumferential and figure-of-eight wiring techniques with orthopaedic wire (20 G). Group 3 (n = 9) was stabilised with the same technique as group 2, but with #2 FiberWire. The knee joints were positioned and fixed in the neutral standing angle (135°) and tested by applying tensile force. The loads at gap formations of 1, 2 and 3 mm were recorded, and the maximum failure load was measured in each group. Results In all the loads at displacement (1, 2 and 3 mm), group 3 was significantly stronger than groups 1 and 2, respectively (P <0.017). Group 3 (261.0 ± 52.8 N) showed significantly stronger fixation in the maximum load compared with group 1 (172.9 ± 45.6 N) (P <0.017). No significant difference was observed between groups 1 and 2 (204.9 ± 68.4 N) or between groups 2 and 3. Conclusions and relevance This study shows that the combination of circumferential and figure-of-eight techniques with FiberWire is more resistant to displacement than metal wire in this ex vivo feline patella fracture model.

Keywords: group; patella; fracture model; patella fracture; fixation

Journal Title: Journal of Feline Medicine and Surgery
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.