LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Combined phacoemulsification and iStent inject implantation in Asian eyes.

Photo from wikipedia

PURPOSE To evaluate the safety and efficacy of the iStent inject device combined with phacoemulsification in Asian eyes with primary open angle glaucoma. METHODS A retrospective study of combined phacoemulsification… Click to show full abstract

PURPOSE To evaluate the safety and efficacy of the iStent inject device combined with phacoemulsification in Asian eyes with primary open angle glaucoma. METHODS A retrospective study of combined phacoemulsification and iStent inject surgeries performed in a single institution from July 2017 to August 2019 on patients with co-existing cataracts and primary open angle glaucoma (POAG). Outcome measures included best-corrected visual acuity, intraocular pressure (IOP), number of glaucoma eyedrop medications, and surgical complications. RESULTS A total of 95 eyes were included. Majority of subjects were male (59, 62.1%) and Chinese (83, 87.4%). Mean age was 74.7 ± 8.7 years. Pre-operatively, mean IOP was 16.2 ± 4.3 mmHg and number of medications was 1.9 ± 0.9. Significant post-operative reduction in mean IOP was observed at all timepoints - post-operative month (POM)1: 3.0 ± 5.6 mmHg reduction (n = 95, p < 0.05); POM3: 1.6 ± 3.8 mmHg (n = 66, p < 0.05); POM6: 1.8 ± 4.7 mmHg (n = 55, p < 0.05); POM12: 1.3 ± 4.2 mmHg (n = 48) (p < 0.05). The number of glaucoma medications was also reduced from a mean of 1.9 ± 0.8 to 0.6 ± 1.0 at POM12 (p < 0.05). Intraoperatively, one case of malignant glaucoma occurred. Post operatively, implant obstruction by iris was observed in two eyes post-operatively requiring iridoplasty. One case of cystoid macular edema and one case of drop in visual acuity due to glaucoma progression was/were also observed. CONCLUSION Asian eyes undergoing combined phacoemulsification and iStent inject surgery demonstrate a significant and sustained reduction in both IOP and number of glaucoma medications. Overall, there is a good safety profile for iStent inject.

Keywords: glaucoma; combined phacoemulsification; asian eyes; istent inject

Journal Title: European journal of ophthalmology
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.