LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

The fate of sagittal alignment in tapered uncemented femoral components in total hip arthroplasty: 889 hips followed for a minimum of 10 years

Photo from wikipedia

Purpose: Aseptic loosening is rare after primary total hip arthroplasty (THA) with mostly uncemented tapered stems; however, different factors can modify the results. We question whether 3 different current femoral… Click to show full abstract

Purpose: Aseptic loosening is rare after primary total hip arthroplasty (THA) with mostly uncemented tapered stems; however, different factors can modify the results. We question whether 3 different current femoral components and/or the surgical technique affect the clinical and radiological outcome after a minimum follow-up of 10 years. Methods: 889 uncemented tapered stems implanted from 1999 to 2007 were evaluated for a minimum follow-up of 10 years. Group 1 (273 hips) shared a conical shape and a porous-coated surface, group 2 (286 hips) a conical splined shape and group 3 (330 hips) a rectangular grit-blasted stem. Groups 1 and 2 were implanted through a posterolateral approach and group 3 using an anterolateral approach. Clinical outcomes and anteroposterior and sagittal radiographic analyses were compared. Results: No thigh pain was reported in unrevised patients. Mean Harris Hip score was lower for patients in group 3 for pain and function at all intervals. 14-year implant survival for aseptic loosening was 98.2% (95% confidence interval [CI] 96.2–100) in group 3. No revision for aseptic loosening was found with the other designs. A stem position outside neutral limits in the sagittal alignment (p = 0.001, hazard ratio: 6.17, 95% CI, 2.05–18.61) was associated with aseptic loosening in group 3. Conclusions: Most current uncemented straight tapered femoral components can provide adequate bone fixation in primary THA after 10 years. Conical stems inserted through a posterolateral approach are more reliable than rectangular ones inserted through an anterolateral approach.

Keywords: hip; femoral components; group; aseptic loosening; hip arthroplasty; total hip

Journal Title: HIP International
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.