LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Clinical and Echocardiographic Outcomes After Aortic Valve Repair Surgery

Photo from wikipedia

Objective To assess early and late clinical outcomes in patients who underwent aortic valve repair surgery for aortic valve insufficiency, and to investigate predictors for recurrence. Methods Of 151 consecutive… Click to show full abstract

Objective To assess early and late clinical outcomes in patients who underwent aortic valve repair surgery for aortic valve insufficiency, and to investigate predictors for recurrence. Methods Of 151 consecutive patients who underwent aortic valve repair surgery for varying degrees of aortic insufficiency (AI) in our department between 2004 and 2018, 60 (40%) underwent aortic root replacement, 71 (47%) aortic cusp plication, 31 (20%) subcommissural annuloplasty, 29 (19%) circular annuloplasty, and 28 (18%) autologous pericardial patch augmentation. Results One patient died in the hospital (0.7%). Mean clinical and echocardiographic follow-up was 62±43 months (range 1 to 159) and 50 ± 40 months (range 1 to 158), respectively. The overall survival rate was 99.3% at 1 year and 98% at 5 years of follow-up. Seventeen patients (11.3%) had recurrent severe AI, and all of them underwent reoperation with a mean duration to reoperation of 35 ± 39 months. Risk factors for the development of recurrent significant AI (≥3) or reoperation, by univariable analysis, were unicuspid or bicuspid aortic valve (AV) (P = 0.018), the use of subcommissural annuloplasty (P = 0.010), the need for cusp repair (P = 0.001), and the use of pericardial patch augmentation (P < 0.001). By multivariable analysis only the use of pericardial patch augmentation emerged as a significant independent predictor for the development of recurrent significant AI (≥3) or reoperation (P = 0.020). Conclusion AV repair can be performed with low morbidity and mortality, with good early and late clinical outcomes. However, in our experience there was a significant rate of recurrent AI especially in patients who underwent cusp augmentation using glutaraldehyde-treated autologous pericardial patch.

Keywords: valve repair; clinical echocardiographic; pericardial patch; aortic valve; repair surgery; repair

Journal Title: Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.