PURPOSE To evaluate the method of thrombin injection under B-flow and ultrasound guidance (BUGTI) for the treatment of pseudoaneurysms. MATERIALS AND METHODS Twenty-one patients suffering from pseudoaneurysm (PSA) were retrospectively… Click to show full abstract
PURPOSE To evaluate the method of thrombin injection under B-flow and ultrasound guidance (BUGTI) for the treatment of pseudoaneurysms. MATERIALS AND METHODS Twenty-one patients suffering from pseudoaneurysm (PSA) were retrospectively reviewed at the First Affiliated Hospital of Nanjing Medical University in Nanjing, China, from January 2018 to August 2019. The patients were treated using an ultrasound-guided injection of thrombin (500 IU/mL) combined with B-mode blood flow imaging (B-flow). The information on the PSA, including the size of the arterial rupture and sac, flow rate, thrombin dose, and treatment outcome, was recorded during the procedure. Follow-up evaluation was performed at 1, 3, and 6 months after the treatment. Pearson's correlation analysis was performed among the characteristics of PSA and the dose of thrombin. RESULT The age of patients ranged from 34 to 80 years and averaged 62.8 years. The maximum cross-sectional area of PSA ranged from 208 to 1148 mm2. All patients were treated with thrombin injections. The dose of thrombin ranged from 300 to 1667 IU. No reperfusions were detected at follow-up 6 months, and the BUGTI treatment was successful in all 21 cases. Pearson's correlation analysis demonstrated that the dose of thrombin was positively correlated with the width (r = 0.449, p < .05) and maximum cross-sectional area (r = 0.504, p < .05) of PSA. CONCLUSION Thrombin injection under B-flow and ultrasound guidance is a rapid and effective treatment for PSA. Additionally, the sac size could be used to estimate the dose of thrombin.
               
Click one of the above tabs to view related content.