Clinical Accuracy of a Glucose Oxidase-Based Blood Glucose Test-Strip Across Extremes of Oxygen Partial Pressure.

Photo from wikipedia

BACKGROUND Glucose oxidase (GOx)-based blood glucose monitors (BGMs) are influenced by the partial pressure of oxygen (Po2) within the applied sample. Limited in-clinic data exists regarding the quantitative effect of… Click to show full abstract

BACKGROUND Glucose oxidase (GOx)-based blood glucose monitors (BGMs) are influenced by the partial pressure of oxygen (Po2) within the applied sample. Limited in-clinic data exists regarding the quantitative effect of Po2 in unmanipulated capillary fingertip blood samples across physiologically representative glucose and Po2 ranges. METHOD Clinical accuracy data were collected as part of a BGM manufacturer's ongoing post-market surveillance program for a commercially available GOx-based BGM test-strip. The data set comprised 29 901 paired BGM-comparator readings and corresponding Po2 values from 5 428 blood samples from a panel of 975 subjects. RESULTS A linear regression-calculated bias range of 5.22% (+0.72% [low Po2: 45 mm Hg] to -4.5% [high Po2: 105 mm Hg]); biases calculated as absolute at <100 mg/dL glucose was found. Below the nominal Po2 of 75 mm Hg, a linear regression bias of +3.14% was calculated at low Po2, while negligible impact on bias (regression slope: +0.002%) was observed at higher than nominal levels (>75 mm Hg). When evaluating BGM performance under corner conditions of low (<70 mg/dL) and high (>180 mg/dL) glucose, combined with low and high Po2, linear regression biases ranged from +1.52% to -5.32% within this small group of subjects and with no readings recorded at <70 mg/dL glucose at low and high Po2. CONCLUSIONS Data from this large-scale clinical study, performed on unmanipulated fingertip capillary bloods from a diverse diabetes population, indicate Po2 sensitivity of the BGM to be markedly lower than published studies, which are mainly laboratory-based, requiring artificial manipulation of oxygen levels in aliquots of venous blood.

Keywords: blood glucose; po2; partial pressure; blood; based blood; glucose oxidase

Journal Title: Journal of diabetes science and technology
Year Published: 2023