LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Validating the Cambridge Protocol: Reliability of Hip Muscle Strength Measurements Using a Motorized Dynamometer and Electromyography.

Photo from wikipedia

BACKGROUND Muscle weakness is common after injury in athletes and in the presence of hip pathology. It will cause abnormal hip biomechanics and can predict future injury. However, objective measurement… Click to show full abstract

BACKGROUND Muscle weakness is common after injury in athletes and in the presence of hip pathology. It will cause abnormal hip biomechanics and can predict future injury. However, objective measurement of hip muscle strength is difficult to perform accurately and reliably. Therefore, it is challenging to determine when an athlete has returned to preinjury levels of strength. In addition, there is currently no standardized method of obtaining measurements, which prevents the data being compared or shared between research centers. PURPOSE The purpose of this study is to comprehensively assess the inter- and intraobserver reliability of our standardized muscle strength measurement protocol. STUDY DESIGN Descriptive laboratory study. LEVEL OF EVIDENCE Level 3, inception cohort study. METHODS A total of 16 healthy male volunteers (age = 28.3 ± 7.9 years) were recruited. Those with a previous history of hip injuries or disorders were excluded. These volunteers underwent strength testing according to the Cambridge Protocol on 4 separate occasions, performed by 2 independent assessors. Maximal voluntary contractions, fatigue torque fluctuations, and electromyography measurements were recorded. Intra- and interobserver reliability was assessed using intraclass correlation coefficient (ICC). RESULTS Good-to-excellent correlation was seen for both intra- and interobserver reliability across almost all hip movements for maximal contractions: ICC ranged 0.78 to 0.93 and 0.78 to 0.96, respectively. The standard error of the mean for all hip movements was also extremely low at 2% to 3%. CONCLUSION The Cambridge Protocol is a highly reliable method for objective measurement of hip muscle strength. We recommend future studies use this protocol, or the principles underpinning it, to enable data sharing and comparison across different studies. CLINICAL RELEVANCE This is a description and analysis of hip muscle strength measurement. If widely used, it will allow for accurate and objective strength assessment and closer monitoring of hip injuries and pathology.

Keywords: hip muscle; hip; muscle strength; strength; reliability

Journal Title: Sports health
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.