LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

High-resolution manometry is superior to endoscopy and radiology in assessing and grading sliding hiatal hernia: A comparison with surgical in vivo evaluation

Photo by owenbeard from unsplash

Background Hiatal hernia is diagnosed by barium-swallow esophagogram or esophagogastroduodenoscopy, with possible suboptimal results. High-resolution manometry clearly identifies crural diaphragm and lower esophageal sphincter. Objectives To assess the diagnostic accuracy… Click to show full abstract

Background Hiatal hernia is diagnosed by barium-swallow esophagogram or esophagogastroduodenoscopy, with possible suboptimal results. High-resolution manometry clearly identifies crural diaphragm and lower esophageal sphincter. Objectives To assess the diagnostic accuracy of high-resolution manometry in detecting hiatal hernia compared to esophagogram and esophagogastroduodenoscopy, using as reference the surgical in vivo measurement. Methods Patients were studied with esophagogram, esophagogastroduodenoscopy, high-resolution manometry and in vivo evaluation of the esophago-gastric junction. Esophago-gastric junction was classified as type I (no separation between crural diaphragm and lower esophageal sphincter); type II (≥1, ≤ 2 cm separation); type III (>2 cm). During in vivo measurement, distance between the esophago-gastric junction and crural diaphragm proximal border was recorded. Results Surgery identified 53 hiatal hernias in 100 patients. Forty-seven percent were classified as type I esophago-gastric junction, 35% type II and 18% type III. Referenced to in vivo evaluation, high-resolution manometry showed superior diagnostic sensitivity and specificity (94.3% and 91.5%, respectively) to esophagogram and esophagogastroduodenoscopy, with 92.6% predictive value of a positive test and 93.5% predictive value of a negative test. The kappa value for high-resolution manometry and in vivo evaluation was 0.85. High-resolution manometry showed optimal sensitivity and specificity in detecting types I, II and III esophago-gastric junction. Conclusions High-resolution manometry enables an accurate diagnosis of hiatal hernia and a better classification than endoscopy and radiology, reaching optimal agreement with in vivo assessment.

Keywords: radiology; high resolution; resolution manometry; vivo

Journal Title: United European Gastroenterology Journal
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.