Background: Although experts have advocated for regionally specific heat safety guidelines for decades, guidelines have not been universally adopted. Purpose: To describe the rate and risk factors associated with exertional… Click to show full abstract

Background: Although experts have advocated for regionally specific heat safety guidelines for decades, guidelines have not been universally adopted. Purpose: To describe the rate and risk factors associated with exertional heat illness (EHI). Study Design: Descriptive epidemiology study. Methods: For a 3-month period (August-October) over 6 years (2013-2018), athletic trainers at 13 high schools in North Central Florida recorded varsity football practice time and length, wet-bulb globe temperature (WBGT), and incidences of EHI, including heat stroke, heat exhaustion, and heat syncope. Results: Athletes sustained 54 total EHIs during 163,254 athlete-exposures (AEs) for the 3-month data collection periods over 6 years (incidence rate [IR], 3.31 /10,000 AEs). Heat exhaustion accounted for 59.3% (32/54), heat syncope 38.9% (21/54), and heat stroke 1.9% (1/54) of all EHIs recorded. Of the EHIs, 94.4% (51/54) were experienced within the first 19 practices. The first 19 practices had an IR of 7.48 of 10,000 AEs, and the remaining 44 practices had an IR of 0.32 of 10,000 AEs, demonstrating that the risk of EHI for practices 1 to 19 was 23.7 times that of the remaining practices. When comparing morning to afternoon practices, 35.2% (19/54) EHI incidents occurred during morning practices. The risk of EHI during practices with WBGT >82°F (27.8°C) was 3.5 times that of practices with WBGT <82°F. Conclusion: In the current study, the risk of EHI was greatest in the first 19 practices of the season and during practices with WBGT >82°F. As modifiable risk factors for EHI, increased vigilance and empowerment to adhere to acclimatization guidelines can mitigate EHI risk. Health care providers must continue to advocate for implementation of regulations and the authority to make decisions to ensure patient safety.

Keywords: risk; rate; heat; exertional heat; central florida; north central

Journal Title: Orthopaedic Journal of Sports Medicine
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.