LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Continuous quality monitoring in the field: an evaluation of the performance of the Fio Deki Reader™ for rapid HIV testing in South Africa

Photo from wikipedia

Background Rapid diagnostic tests (RDTs) are a cornerstone of HIV diagnosis and rely on good quality processing and interpretation, particularly in the era of test and treat. The Deki Reader… Click to show full abstract

Background Rapid diagnostic tests (RDTs) are a cornerstone of HIV diagnosis and rely on good quality processing and interpretation, particularly in the era of test and treat. The Deki Reader (Fio Corporation®, Toronto, Ontario, Canada) is a portable device designed specifically for analysing RDTs and was selected for evaluation in South Africa in the context of HIV RDT analysis. Methods This study consisted of a laboratory evaluation and two-part field evaluation of the Deki Reader v100, covering two RDT testing algorithms, and an evaluation of the continuous quality monitoring through the Fionet™ web portal. Based on user feedback from the field evaluation, the device underwent hardware and software redesign, and the Deki Reader v200 was evaluated in the laboratory. Ethics approval for this evaluation was obtained from the University of the Witwatersrand Human Research Ethics Committee: M150160. Results The intra- and inter-device laboratory precision of the Deki Reader v100 were 98.3 and 99.2% respectively, and 99.3 and 100% for the Deki Reader v200. The laboratory concordances compared to standard-of-care reporting were 99.5 and 98.0% for the two respective models, while sensitivity and specificity were 99.5 and 99.4% for the Deki Reader V100 and 100 and 93.1% for the Deki Reader V200 respectively. Screening and confirmatory concordances in the field were 99.3 and 96.5% under algorithm 1 and 99.7 and 100% under algorithm 2. Sensitivity and specificity for the field evaluation were 99.8 and 97.7%. Overall robustness of the device was acceptable and continuous quality monitoring through Fionet™ was feasible. Conclusions The Deki Reader provides an option for improved and reliable quality assessment for rapid diagnosis of HIV using RDTs to enhance the quality of healthcare at the point-of-care. However, the introduction of new RDTs and modification of current algorithms necessitates ongoing and agile RDT reader adjustments, which will require cost modelling to ensure sustainability of devices implemented into national HIV programs.

Keywords: quality; reader; hiv; evaluation; deki reader

Journal Title: BMC Infectious Diseases
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.