LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Assessment of meibomian glands using a custom–made meibographer in dry eye patients in Ghana

Photo from wikipedia

BackgroundMeibomian Gland Dysfunction (MGD) is a leading cause of evaporative Dry Eye Disease (DED). This makes non-invasive meibography an important procedure in the clinical evaluation of DED patients. Our purpose… Click to show full abstract

BackgroundMeibomian Gland Dysfunction (MGD) is a leading cause of evaporative Dry Eye Disease (DED). This makes non-invasive meibography an important procedure in the clinical evaluation of DED patients. Our purpose was to conduct a lead-off investigation focused on the practicality of performing meibography in a developing country, with limited access to complex ophthalmic imaging systems, using a custom meibographer, as a step to future comparative studies on meibomian glands and DED in Africa.MethodsMeibomian glands(MG) in 76 upper eyelids (UL) and 49 lower eyelids (LL) in 1 eye each of 125 patients randomly selected from a patient population presenting with subjective DED symptoms at a clinic were photographed using a custom meibographer. Single frames were captured, and the MG area determined by intensity threshold segmentation and area calculation using Image J software. MG loss (MGL) was quantified by outlining its area and expressing it as a percentage of the total MG per Pult’s grading scheme. Dry eye measures included Tear Film Break Up - Time (TUBT), Schirmer’s test and Ocular Surface Staining (OSS). Symptoms were evaluated using the SPEED II questionnaire. Correlations between MGL and age, ocular signs and symptoms were analyzed by Pearson’s. Differences between comparable groups were analyzed by Mann - Whitney test; p < 0.05 was considered significant.ResultsOverall mean MGL was 32.10% ± 25.0% (26.25% ± 22.40% for UL and 40.33% ± 26.70% for LL). MGL correlated significantly with age [r = 0.91, p = 0.001], SPEED scores [r = 0.90, p = 0.001], OSS [r = 0.75, p = 0.001] and TBUT [r = − 0.81, p = 0.001]. MGL scores were significantly higher in the UL than LL [U = 1293.5 p = 0.004].ConclusionThis study for the first time presents data on the status of Meibomian glands in Africa. It furthermore suggests that it is feasible to examine Meibomian glands using a custom meibographer in developing countries with limited access to complex imaging systems. It also demonstrates the benefit and cost-effectiveness of a simple device by the observed significant relations between meibomian gland loss and DED in these patients.

Keywords: meibomian glands; using custom; dry eye; glands using

Journal Title: BMC Ophthalmology
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.