BackgroundLittle data are available regarding the effects of pedicle screws on the intervertebral disc stress for different spinal segments. The aim of this study was to analyze the intervertebral disc… Click to show full abstract
BackgroundLittle data are available regarding the effects of pedicle screws on the intervertebral disc stress for different spinal segments. The aim of this study was to analyze the intervertebral disc stress in response to the placement of pedicle screws.MethodsT3–4, T11–12, T15–L1, L3–4, and L4–5 intervertebral disc segments from six porcine spine specimens were harvested. A compressive load of 200 N was applied both before and after the pedicle screw was implanted on the left side of each target segment; the resulting pressure was measured during vertical, 5° anterior flexion, 5° posterior extension, and 5° lateral bending.ResultsThe posterior intradiscal pressures of the intervertebral disc were significantly lower in the fixed group than in the unfixed group for all segments during vertical, 5° anterior flexion, and 5° posterior extension. The left pressures of the intervertebral disc were significantly lower in the fixation group for all segments. During 5° lateral bending, the left intervertebral disc pressures were significantly lower in the fixation group. Lower mean pressures were observed in the fixed group.ConclusionsUnilateral pedicle screws can effectively reduce the pressure of the fixed lateral intervertebral disc. Moreover, it can change the pressure distribution of the intervertebral disc and reduce the pressure of the entire intervertebral disc, especially the posterior side of the intervertebral disc.
               