LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Usefulness of silent magnetic resonance angiography (MRA) for the diagnosis of atherosclerosis of the internal carotid artery siphon in comparison with time-of-flight MRA

Photo by windclems from unsplash

Background and purpose Flow visualization in 3D time-of-flight MRA (3D-TOF MRA) may be limited for internal carotid artery siphon owing to turbulent artifact. The purpose of this study was to… Click to show full abstract

Background and purpose Flow visualization in 3D time-of-flight MRA (3D-TOF MRA) may be limited for internal carotid artery siphon owing to turbulent artifact. The purpose of this study was to compare the usefulness of Silent MRA and 3D-TOF MRA to assess atherosclerosis of the internal carotid artery siphon. Material and methods A total of 106 patients with suspected cerebrovascular disease were included. All patients were scanned with Silent MRA and 3D-TOF MRA sequences and also underwent DSA examination. Two observers independently assessed the TOF MRA and Silent MRA images of atherosclerosis of the internal carotid artery siphon. The diagnostic efficacy of two MRA methods in evaluating atherosclerosis of the carotid siphon was performed by using receiver operating characteristic (ROC) curve analysis. Interobserver reliability was also assessed using weighted kappa statistics. Results Image of Silent MRA sequence had higher subjective evaluation scores and significantly high CNR between the carotid siphon and the background tissues than the image of 3D-TOF MRA sequence ( P  < 0.05). The AUC was 0.928 (95% CI 0.909–0.986) for Silent MRA, which was significantly higher than that of 3D-TOF MRA (0.671, 95% CI 0.610–0.801, P  < 0.05). Silent MRA had high sensitivity, specificity and accuracy than 3D-TOF MRA for visualization of the carotid siphon. Conclusions Silent MRA as a new angiographic modality is superior to 3D-TOF MRA for visualization of the carotid siphon, and maybe an alternative to 3D-TOF MRA in the diagnosis of atherosclerosis of the carotid siphon.

Keywords: mra; carotid; silent mra; siphon; tof mra

Journal Title: European Journal of Medical Research
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.