LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Fat-suppressed gadolinium-enhanced isotropic high-resolution 3D-GRE-T1WI for predicting small node metastases in patients with rectal cancer

Photo from wikipedia

BackgroundTo investigate the application value of fat-suppressed gadolinium-enhanced isotropic high-resolution 3D-GRE-T1WI in regional nodes with different short-axis diameter ranges in rectal cancer, especially in nodes ≤5 mm.MethodsPatients with rectal adenocarcinoma confirmed… Click to show full abstract

BackgroundTo investigate the application value of fat-suppressed gadolinium-enhanced isotropic high-resolution 3D-GRE-T1WI in regional nodes with different short-axis diameter ranges in rectal cancer, especially in nodes ≤5 mm.MethodsPatients with rectal adenocarcinoma confirmed by postoperative histopathology were included, and all the patients underwent preoperative 3.0 T rectal magnetic resonance imaging (MRI) and total mesorectal excision (TME) within 2 weeks after an MR scan. The harvested nodes from specimens were matched with nodes in the field of view (FOV) of images for a node-by-node evaluation. The maximum short-axis diameters of all the visible nodes in the FOV of images were measured by a radiologist; the morphological and enhancement characteristics of these nodes were also independently evaluated by two radiologists. The χ2 test was used to evaluate differences in morphological and enhancement characteristics between benign and malignant nodes. The enhancement characteristics were further compared between benign and malignant nodes with different short-axis diameter ranges using the χ2 test. Kappa statistics were used to describe interobserver agreement.ResultsA total of 441 nodes from 70 enrolled patients were included in the evaluation, of which 111 nodes were metastatic. Approximately 85.5 and 95.6% of benign nodes were found to have obvious enhancement and homogeneous or mild-heterogeneous enhancement, respectively, whereas approximately 89.2 and 85.1% of malignant nodes showed moderate or mild enhancement and obvious-heterogeneous or rim-like enhancement, respectively. The area under the receiver operating characteristic (ROC) curve (AUC) values of the enhancement degree for identifying the overall nodal status, nodes ≤5 mm and nodes > 5 mm and ≤ 10 mm were 0.887, 0.859 and 0.766 for radiologist 1 and 0.892, 0.823 and 0.774 for radiologist 2, respectively. The AUCs of enhancement homogeneity were 0.940, 0.928 and 0.864 for radiologist 1 and 0.944, 0.938 and 0.842 for radiologist 2, respectively. Nodal border and signal homogeneity were also of certain value in distinguishing metastatic nodes.ConclusionsEnhancement characteristics based on fat-suppressed gadolinium-enhanced isotropic high-resolution 3D-GRE-T1WI were helpful for diagnosing metastatic nodes in rectal cancer and were a reliable indicator for nodes ≤5 mm.

Keywords: gadolinium enhanced; enhanced isotropic; fat suppressed; enhancement; cancer; suppressed gadolinium

Journal Title: Cancer Imaging
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.