Dehiscence and Deep Wound Infection After Spinal Cord Stimulator Implant Managed Without Explantation: A Case Report.

Photo from wikipedia

Deep infections of spinal cord stimulator devices usually result in explantation, as recommended by some professional societies. However, alternative options should be explored to avoid potential complications that are associated… Click to show full abstract

Deep infections of spinal cord stimulator devices usually result in explantation, as recommended by some professional societies. However, alternative options should be explored to avoid potential complications that are associated with explantation, and possibly additional procedures required in consideration of reimplantation. In this case, the patient presented with wound dehiscence after implantation. There was suspicion for deep wound infection based on a wound culture that was positive for Staphylococcus aureus, but no purulent material was noted on further inspection. The patient was treated with standard wound-care management and oral antibiotics without removing the device, and recovered while preserving the original system.

Keywords: wound infection; spinal cord; cord stimulator; deep wound; explantation