LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Identification of selected primary bloodstream infection pathogens in patients attending Kisii level five and Homa Bay county hospitals

Photo from wikipedia

Background: Bloodstream infection (BSI) contributes to a substantial proportion of mortality in sub-Saharan Africa and is marked by the presence of bacterial and/or fungal microorganisms in the blood. Because BSI… Click to show full abstract

Background: Bloodstream infection (BSI) contributes to a substantial proportion of mortality in sub-Saharan Africa and is marked by the presence of bacterial and/or fungal microorganisms in the blood. Because BSI can be life threatening, it requires a timely, reliable and accurate diagnosis. This study retrospectively analyzed data of identified BSI pathogens and compared the performance of the different diagnostic technologies used in terms of accuracy, sensitivity, turnaround time (TAT) and cost. Methods: Currently, culture followed by analytical profile index biochemical strips (API), (BioMerieux) are used as the conventional standard diagnostics in Kenyan public hospitals and labs. We compared the results of this standard to that of the BioFire FilmArray (FA) (BioFire Diagnostics) and MicroScan WalkAway-40 plus System (MS) (Beckman Coulter) used in diagnosis of BSI. The FA technology was able to identify 150/152 bacterial and yeast isolates with an overall accuracy of 99.04% (95% CI: 96.59-99.88%), sensitivity of 98.68% (95% CI: 95.33-99.84%), mean TAT of 8 hours 40 minutes per eight samples and running cost per sample of USD 140.11. The MS identified 150/152 isolates with an overall accuracy of 98.56% (95% CI: 95.86-99.70%), sensitivity of 98.68% (95% CI: 95.30-99.84%), mean TAT per sample was 42 hours and running cost per sample of USD 28.05. API detected 150/152 isolates, with an overall accuracy of 99.04% (95% CI: 96.59-99.88%), sensitivity of 98.68% (95% CI: 95.33-99.84%) and the mean TAT per sample was 53 and 103 hours for bacterial and yeast samples, respectively, with a running cost per sample of USD 28.05. Conclusions: The findings in this paper suggest that the FA and MS platforms should be able to perform adequately in Kenya referral hospitals and medical clinics as a rapid diagnostic tool.

Keywords: sample; bloodstream infection; per sample; accuracy sensitivity

Journal Title: F1000Research
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.