LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Functional capacity and ventilatory efficiency are preserved in well-controlled people living with human immunodeficiency virus/acquired immunodeficiency syndrome

Photo by kaidj from unsplash

To verify and compare the responses of the cardiopulmonary variables to the incremental test in physically inactive people living with human immunodeficiency virus (HIV)/acquired immune deficiency syndrome (AIDS) (PLWHA) with… Click to show full abstract

To verify and compare the responses of the cardiopulmonary variables to the incremental test in physically inactive people living with human immunodeficiency virus (HIV)/acquired immune deficiency syndrome (AIDS) (PLWHA) with well-controlled disease and physically inactive healthy subjects (non-HIV/AIDS). Participants performed a cardiopulmonary exercise test (CPX) on a treadmill. Data were analyzed using the Mann–Whitney test and Spearman correlation. Nine PLWHA (5 women) and 9 non-HIV/AIDS gender and activity level-matched controls were included in the data analysis. Data are expressed in median (range). No difference was shown in the PLWHA group when compared to the control group in functional capacity (peak oxygen consumption [VO2peak]: 29.9 (20.9–36.4) mL/kg/min vs. 32.2 (24.5–39.4) mL/kg/min) and ventilatory efficiency (oxygen uptake efficiency slope [OUES]: 2,058 [1,474–3,204] vs. 2,612 [1,383–4,119]; minute ventilation carbon dioxide production slope: 27.4 [22.5–33.6] vs. 27.5 [20.4–38.1]). The results are also similar to maximal heart rate, oxygen pulse, gas exchange threshold, respiratory compensation point, heart rate recovery, and half-time of VO2peak recovery. OUES had a strong correlation with VO2peak in the PLWHA group (rs=0.70, P=0.04) and control group (rs=0.78, P=0.02). The results of this study indicate that functional capacity and ventilatory efficiency in PLWHA with well-controlled disease are preserved and are not different from sedentary subjects. In this sense, when CPX is unavailable, the aerobic assessment and prescription could be based on simpler procedures used in healthy subjects.

Keywords: immunodeficiency; well controlled; ventilatory efficiency; functional capacity; efficiency

Journal Title: Journal of Exercise Rehabilitation
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.