The study of Rayleigh-Taylor (RT) and Richtmyer-Meshkov (RM) instabilities in a planar geometry at high energy densities at the National Ignition Facility (NIF) requires high spatial resolution imaging. We demonstrate… Click to show full abstract
The study of Rayleigh-Taylor (RT) and Richtmyer-Meshkov (RM) instabilities in a planar geometry at high energy densities at the National Ignition Facility (NIF) requires high spatial resolution imaging. We demonstrate the potential of Fresnel zone plates (FZPs) to achieve resolution that would unlock such studies. FZPs are circular aperiodic gratings that use diffraction to focus x rays and produce an image with high spatial resolution. Taking into account the NIF's challenging environment, we have designed a specific array of five FZPs for a zinc backlighter to take a radiograph of a target with 9 keV x rays. We measured a mean resolution for the FZP of 1.9µm±0.5µm and a ±1mm depth of focus at an x-ray calibration facility as well as a 2.3µm±0.4µm resolution on a resolution wire mesh shot on the NIF. We also performed an in-depth analysis of the image quality to assess the capability to resolve the small features present in RT and RM instabilities.
               
Click one of the above tabs to view related content.