LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Depth-resolved visualization and automated quantification of hyperreflective foci on OCT scans using optical attenuation coefficients.

Photo from wikipedia

An automated depth-resolved algorithm using optical attenuation coefficients (OACs) was developed to visualize, localize, and quantify hyperreflective foci (HRF) seen on OCT imaging that are associated with macular hyperpigmentation and… Click to show full abstract

An automated depth-resolved algorithm using optical attenuation coefficients (OACs) was developed to visualize, localize, and quantify hyperreflective foci (HRF) seen on OCT imaging that are associated with macular hyperpigmentation and represent an increased risk of disease progression in age related macular degeneration. To achieve this, we first transformed the OCT scans to linear representation, which were then contrasted by OACs. HRF were visualized and localized within the entire scan by differentiating HRF within the retina from HRF along the retinal pigment epithelium (RPE). The total pigment burden was quantified using the en face sum projection of an OAC slab between the inner limiting membrane (ILM) to Bruch's membrane (BM). The manual total pigment burden measurements were also obtained by combining manual outlines of HRF in the B-scans with the total area of hypotransmission defects outlined on sub-RPE slabs, which was used as the reference to compare with those obtained from the automated algorithm. 6×6 mm swept-source OCT scans were collected from a total of 49 eyes from 42 patients with macular HRF. We demonstrate that the algorithm was able to automatically distinguish between HRF within the retina and HRF along the RPE. In 24 test eyes, the total pigment burden measurements by the automated algorithm were compared with measurements obtained from manual segmentations. A significant correlation was found between the total pigment area measurements from the automated and manual segmentations (P < 0.001). The proposed automated algorithm based on OACs should be useful in studying eye diseases involving HRF.

Keywords: using optical; depth resolved; optical attenuation; oct scans; hrf; attenuation coefficients

Journal Title: Biomedical optics express
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.