LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Sensing based on Bloch surface wave and self-referenced guided mode resonances employing a one-dimensional photonic crystal.

Photo by olivpi from unsplash

Sensing abilities of a one-dimensional photonic crystal (1DPhC) represented by a multilayer dielectric structure are analyzed theoretically and experimentally, using a new wavelength interrogation interference method. The structure comprising a… Click to show full abstract

Sensing abilities of a one-dimensional photonic crystal (1DPhC) represented by a multilayer dielectric structure are analyzed theoretically and experimentally, using a new wavelength interrogation interference method. The structure comprising a glass substrate and six bilayers of TiO2/SiO2 with a termination layer of TiO2 is employed in both gas sensing based on the Bloch surface wave (BSW) resonance and liquid analyte sensing based on a self-referenced guide-mode resonance (GMR). We model the spectral interference reflectance responses in the Kretschmann configuration with a coupling prism made of BK7 glass and show that a sharp dip with maximum depth associated with the BSW excitation is red-shifted as the refractive index (RI) changes in a range of 1-1.005. Thus, a sensitivity of 1456 nm per RI unit (RIU) and figure of merit (FOM) of 91 RIU-1 are reached. Similarly, we model the responses for aqueous solutions of ethanol to show that dips of maximum depth are associated with the GMRs, and the highest sensitivity and FOM reached are 751 nm/RIU and 25 RIU-1, respectively. Moreover, we show that one of the dips is with the smallest shift as the RI changes, and hence it can be used as a reference. The theoretical results are confirmed by the experimental ones when the BSW resonance is used in sensing of humid air with a sensitivity of 0.027 nm/%relative humidity (RH) and FOM of 1.4×10-3 %RH-1. Similarly, the GMR is used in sensing of aqueous solutions of ethanol, and the highest sensitivity and FOM reached 682 nm/RIU and 23 RIU-1, respectively. The reference dip is also resolved and this self-reference makes the measurement more accurate and repeatable, and less sensitive to optomechanical drifts.

Keywords: riu; sensing based; based bloch; one dimensional; dimensional photonic; photonic crystal

Journal Title: Optics express
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.