LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Septic Systems Contribution to Phosphorus in Shallow Groundwater: Field-Scale Studies Using Conventional Drainfield Designs

Photo from wikipedia

Septic systems can be a potential source of phosphorus (P) in groundwater and contribute to eutrophication in aquatic systems. Our objective was to investigate P transport from two conventional septic… Click to show full abstract

Septic systems can be a potential source of phosphorus (P) in groundwater and contribute to eutrophication in aquatic systems. Our objective was to investigate P transport from two conventional septic systems (drip dispersal and gravel trench) to shallow groundwater. Two new in-situ drainfields (6.1 m long by 0.61 m wide) with a 3.72 m2 infiltrative surface were constructed. The drip dispersal drainfield was constructed by placing 30.5 cm commercial sand on top of natural soil and the gravel trench drainfield was constructed by placing 30.5 cm of gravel on top of 30.5 cm commercial sand and natural soil. Suction cup lysimeters were installed in the drainfields (at 30.5, 61, 106.7 cm below infiltrative surface) and piezometers were installed in the groundwater (>300 cm below infiltrative surface) to capture P dynamics from the continuum of unsaturated to saturated zones in the septic systems. Septic tank effluent (STE), soil-water, and groundwater samples were collected for 64 events (May 2012–Dec 2013) at 2 to 3 days (n = 13), weekly (n = 29), biweekly (n = 17), and monthly (n = 5) intervals. One piezometer was installed up-gradient of the drainfields to monitor background groundwater (n = 15). Samples were analyzed for total P (TP), orthophosphate-P (PO4–P), and other–P (TP—PO4-P). The gravel trench drainfield removed significantly (p<0.0001) greater TP (~20%) than the drip dispersal in the first 30.5 cm of the drainfield. However, when STE reached >300 cm in the groundwater, both systems had similar TP reductions of >97%. After 18 months of STE application, there was no significant increase in groundwater TP concentrations in both systems. We conclude that both drainfield designs are effective at reducing P transport to shallow groundwater.

Keywords: groundwater; phosphorus; drainfield designs; septic systems; shallow groundwater

Journal Title: PLoS ONE
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.