LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Mid-term outcomes of the Absorb BVS versus second-generation DES: A systematic review and meta-analysis

Photo from wikipedia

Background Bioresorbable Vascular Scaffolds (BVS) were introduced to overcome some of the limitations of drug-eluting stent (DES) for PCI. Data regarding the clinical outcomes of the BVS versus DES beyond… Click to show full abstract

Background Bioresorbable Vascular Scaffolds (BVS) were introduced to overcome some of the limitations of drug-eluting stent (DES) for PCI. Data regarding the clinical outcomes of the BVS versus DES beyond 2 years are emerging. Objective To study mid-term outcomes. Methods We searched online databases (PubMed/Medline, Embase, CENTRAL), several websites, meeting presentations and scientific session abstracts until August 8th, 2017 for studies comparing Absorb BVS with second-generation DES. The primary outcome was target lesion failure (TLF). Secondary outcomes were all-cause mortality, myocardial infarction, target lesion revascularization (TLR) and definite/probable device thrombosis. Odds ratios (ORs) with 95% confidence intervals (CIs) were derived using a random effects model. Results Ten studies, seven randomized controlled trials and three propensity-matched observational studies, with a total of 7320 patients (BVS n = 4007; DES n = 3313) and a median follow-up duration of 30.5 months, were included. Risk of TLF was increased for BVS-treated patients (OR 1.34 [95% CI: 1.12–1.60], p = 0.001, I2 = 0%). This was also the case for all myocardial infarction (1.58 [95% CI: 1.27–1.96], p<0.001, I2 = 0%), TLR (1.48 [95% CI: 1.19–1.85], p<0.001, I2 = 0%) and definite/probable device thrombosis (of 2.82 (95% CI: 1.86–3.89], p<0.001 and I2 = 40.3%). This did not result in a difference in all-cause mortality (0.78 [95% CI: 0.58–1.04], p = 0.09, I2 = 0%). OR for very late (>1 year) device thrombosis was 6.10 [95% CI: 1.40–26.65], p = 0.02). Conclusion At mid-term follow-up, BVS was associated with an increased risk of TLF, MI, TLR and definite/probable device thrombosis, but this did not result in an increased risk of all-cause mortality.

Keywords: term; term outcomes; bvs versus; mid term; second generation; absorb bvs

Journal Title: PLoS ONE
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.