Sellick maneuver assisted real-time to achieve target force range in simulated environment—A prospective observational cross-sectional study on manikin

Photo from wikipedia

A force sensor system was developed to give real-time visual feedback on a range of force. In a prospective observational cross-section study, twenty-two anaesthesia nurses applied cricoid pressure at a… Click to show full abstract

A force sensor system was developed to give real-time visual feedback on a range of force. In a prospective observational cross-section study, twenty-two anaesthesia nurses applied cricoid pressure at a target range of 30–40 Newtons for 60 seconds in three sequential steps on manikin: Group A (step 1 blinded, no sensor), Group B (step 2 blinded sensor), Group C (step 3 sensor feedback). A weighing scale was placed below the manikin. This procedure was repeated once again at least 1 week apart. The feedback system used 3 different colours to indicate the force range achieved as below target, achieve target, above target. Significantly higher proportion of target cricoid pressure was achieved with the use of sensor feedback in Group C; 85.9% (95%CI: 82.7%-88.7%) compared to when blinded from sensor in Group B; 31.3% (95%CI: 27.4–35.4%). Cricoid force achieved blind (Group B) exceeded force achieved with feedback (Group C) by a mean of 8.0 (95%CI: 5.9–10.2, p<0.0001) and 6.2 (95%CI:4.1–8.3, p< 0.0001) Newtons in round 1 and 2 respectively. Weighing scale read lower than corresponding force sensor by a mean of 8.4 Newtons (95% CI: 7.1–9.7, p<0.0001) in group B and 5.8 Newtons (95% CI: 4.5–7.1, p<0.0001) in Group C. Force sensor visual feedback system enabled application of reproducible target cricoid pressure with less variability and has potential value in clinical use. Using weighing scale to quantify and train cricoid pressure requires a review. Understanding the force applied is the first step to make cricoid pressure a safe procedure.

Keywords: range; group; target; cricoid pressure; force; sensor

Journal Title: PLoS ONE
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.