LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Slit-based irrigation catheters can reduce procedure-related ischemic stroke in atrial fibrillation patients undergoing radiofrequency catheter ablation

Photo by equalstock from unsplash

Open irrigation ablation catheters are now the standard in radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF). Among various irrigation catheters, laser-cut slit-based irrigation system (Cool Flex and FlexAbility) has… Click to show full abstract

Open irrigation ablation catheters are now the standard in radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF). Among various irrigation catheters, laser-cut slit-based irrigation system (Cool Flex and FlexAbility) has a unique design to cool the catheter tip more efficiently. We aimed to assess the safety of slit-based irrigation catheters regarding prevention of procedure-related ischemic complication in AF patients undergoing RFCA. The analysis was performed with Korea University Medicine Anam Hospital RFCA registry. Procedure-related ischemic complication was defined as ischemic stroke or transient ischemic attack (TIA) occurring within 30 days after RFCA. Patients were divided into 3 groups: non-irrigation, hole-based irrigation, and slit-based irrigation catheter groups. A total of 3,120 AF patients underwent first RFCA. Non-irrigation, non-slit-based irrigation, and slit-based irrigation catheters were used in 290, 1,539, and 1,291 patients, respectively. As compared with non-irrigation and non-slit-based irrigation catheter groups, slit-based irrigation catheter group had significantly older age, higher prevalence of non-paroxysmal AF, large left atrial size, and decreased left atrial appendage flow velocity. The CHA2DS2-VASc score was not different among the 3 groups. Procedure-related ischemic complication occurred in 17 patients (0.54%) with 16 ischemic strokes and 1 TIA event: 5/290 (1.72%), 11/1,539 (0.71%), and 1/1,291 (0.08%) events in non-irrigation, non-slit-based irrigation, and slit-based irrigation catheter groups, respectively (p = 0.001). Slit-based irrigation catheter was superior in direct comparison with non-slit-based irrigation catheter (0.71% vs. 0.08%; p = 0.009). Slit-based irrigation catheters were highly effective in preventing procedure-related ischemic complications.

Keywords: slit based; catheter; based irrigation; irrigation catheters; irrigation

Journal Title: PLoS ONE
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.