LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Detecting and monitoring dental plaque levels with digital 2D and 3D imaging techniques

Photo from wikipedia

Detecting and monitoring dental plaque is an important issue in research and clinical practice. In this context, new digital imaging methods that permit permanent documentation of the clinical findings could… Click to show full abstract

Detecting and monitoring dental plaque is an important issue in research and clinical practice. In this context, new digital imaging methods that permit permanent documentation of the clinical findings could be promising tools. The aim of the study was therefore to investigate whether disclosed plaque can be reliably visualised on 2D and 3D images captured with digital intraoral imaging devices. Clinical examination was the reference method. Twenty subjects (27.5±1.2 years) were included and plaque was measured at three different stages: habitual plaque (T1), after 72 h without oral hygiene (T2) and after a subsequent habitual brushing exercise (T3). At each time point, plaque was disclosed followed by the clinical examination and capturing the 2D and 3D images (intraoral-camera CS 1500 and intraoral-scanner CS 3600; Carestream Dental, Germany). Plaque amounts were recorded on oral and vestibular surfaces of the Ramfjord-teeth (16, 21, 24, 36, 41, 44) using the Rustogi-modified-Navy-Plaque-Index (RMNPI) and expressed as percentage of plaque-containing RMNPI areas of all RMNPI areas. At T1, percentages (mean±SD) obtained from the clinical examination, 2D and 3D images were 62.2±10.6, 65.1±10.0 and 64.4±10.6 resp. increasing to 76.9±8.0, 77.9±8.6 and 77.5±9.4 resp. at T2. After toothbrushing (T3), values decreased to 56.3±11.1, 58.2±12.1 and 61.2±10.8 resp. All methods were able to show statistically significant changes in plaque amounts at the different time points with in part statistically significant but minor differences between them. The Bland-Altmann analysis revealed a good agreement between values from both 2D and 3D images with the clinical examination. The agreement of the scores obtained with the both image-based methods for the single RMNPI areas with the clinical examination was mainly classified as substantial to almost perfect. Amounts of plaque can be reliably detected and monitored on 2D images from an intraoral camera and on 3D images from an intraoral scanner.

Keywords: monitoring dental; clinical examination; detecting monitoring; plaque; dental plaque

Journal Title: PLoS ONE
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.