LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Sparsity-based method for ring artifact elimination in computed tomography

Photo from wikipedia

Ring artifact elimination is one of the popular problems in computed tomography (CT). It appears in the reconstructed image in the form of bright or dark patterns of concentric circles.… Click to show full abstract

Ring artifact elimination is one of the popular problems in computed tomography (CT). It appears in the reconstructed image in the form of bright or dark patterns of concentric circles. In this paper, based on the compressed sensing theory, we propose a method for eliminating the ring artifact during the image reconstruction. The proposed method is based on representing the projection data by a sum of two components. The first component contains ideal correct values, while the latter contains imperfect error values causing the ring artifact. We propose to minimize some sparsity-induced norms corresponding to the imperfect error components to effectively eliminate the ring artifact. In particular, we investigate the effect of using different sparse models, i.e. different sparsity-induced norms, on the accuracy of the ring artifact correction. The proposed cost function is optimized using an iterative algorithm derived from the alternative direction method of multipliers. Moreover, we propose improved versions of the proposed algorithms by incorporating a smoothing penalty function into the cost function. We also introduce angular constrained forms of the proposed algorithms by considering a special case as follows. The imperfect error values are constant over all the projection angles, as in the case where the source of ring artifact is the non-uniform sensitivity of the detector. Real data and simulation studies were performed to evaluate the proposed algorithms. Results demonstrate that the proposed algorithms with incorporating smoothing penalty and their angular constrained forms are effective in ring artifact elimination.

Keywords: artifact elimination; computed tomography; sparsity; ring artifact; method

Journal Title: PLoS ONE
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.