Background The two-thumb encircling technique (2TT) is superior to the two-finger technique (2FT) in infant cardiopulmonary resuscitation (CPR), but there are difficulties in providing ventilation as soon as possible. We… Click to show full abstract

Background The two-thumb encircling technique (2TT) is superior to the two-finger technique (2FT) in infant cardiopulmonary resuscitation (CPR), but there are difficulties in providing ventilation as soon as possible. We modified the 2TT to the cross-thumb technique (CTT) to maintain good CPR performance at the same position as 2FT. We aimed to compare the quality of chest compression and brief hands-off times in 2FT, 2TT, and CTT by a single rescuer using an infant CPR manikin model. Methods This study was designed as a prospective randomized controlled simulation-based study. We used the ResusciĀ® Baby QCPR (Laerdal Medical, Stavanger, Norway) as a simulated 3-month-old infant. Ventilation was performed by the mouth-to-mouth technique using a chest compression-to-ventilation ratio of 30:2 as a single rescuer. Data on CPR quality, such as locations, rates, depth and release of chest compressions, hands-off times, and proper ventilation, were recorded using the ResusciĀ® Baby QCPR and SkillReporter. Also, the chest compression fraction (CCF) was automatically calculated. Results The depth of chest compression in 2FT, 2TT, and CTT were 40.0 mm (interquartile range [IQR] 39.0, 41.0), 42.0 mm (IQR 41.0, 43.0), and 42.0 mm (IQR 41.0, 43.0), respectively. The depth of chest compression in 2FT was shallower than that in the other two techniques (P<0.05). CCF in 2FT, 2TT, and CTT were 73.9% (IQR 72.2, 75.6), 71.2% (IQR 67.2, 72.2) and 71.3% (IQR 67.7, 74.1), respectively. CCF was higher in 2FT than in the other two techniques (P<0.05). Correct location in 2FT, 2TT, and CTT were 99.0% (IQR 86.0, 100.0), 100.0% (IQR 97.0, 100.0) and 100.0% (IQR 99.0, 100.0), respectively. Correct location in CTT and 2TT was higher than that in 2FT. Performing CTT, the subjective pain and fatigue score were lower than other two technique. Conclusion A new chest compression technique, CTT was better in chest compression depth compared with 2FT and may be helpful in maintaining correct chest compression location with less pain and fatigue in infant CPR.

Keywords: chest compression; thumb; ctt; compression; iqr; technique

Journal Title: PLoS ONE
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.