LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

A caveat to using wearable sensor data for COVID-19 detection: The role of behavioral change after receipt of test results

Photo from wikipedia

Background Recent studies indicate that wearable sensors can capture subtle within-person changes caused by SARS-CoV-2 infection and play a role in detecting COVID-19 infections. However, in addition to direct effects… Click to show full abstract

Background Recent studies indicate that wearable sensors can capture subtle within-person changes caused by SARS-CoV-2 infection and play a role in detecting COVID-19 infections. However, in addition to direct effects of infection, wearable sensor data may capture changes in behavior after the receipt of COVID test results. At present, it remains unclear to what extent the observed discriminative performance of the wearable sensor data is affected by behavioral changes upon receipt of the test results. Methods We conducted a retrospective study of wearable sensor data in a sample of medical interns who had symptoms and received COVID-19 test results from March to December 2020, and calculated wearable sensor metrics incorporating changes in step, sleep, and resting heart rate for interns who tested positive (cases, n = 22) and negative (controls, n = 83) after symptom onset. All these interns had wearable sensor data available for > 50% of the days in pre- and post-symptom onset periods. We assessed discriminative accuracy of the metrics via area under the curve (AUC) and tested the impact of behavior changes after receiving test results by comparing AUCs of three models: all data, pre-test-result-only data, and post-test-result-only data. Results Wearable sensor metrics differentiated between symptomatic COVID-19 positive and negative individuals with good accuracy (AUC = 0.75). However, the discriminative capacity of the model with pre-test-result-only data substantially decreased (AUC from 0.75 to 0.63; change = -0.12, p = 0.013). The model with post-test-result-only data did not produce similar reductions in discriminative capacity. Conclusions Changes in wearable sensor data, especially physical activity and sleep, are robust indicators of COVID-19 infection, though they may be reflective of a person’s behavior change after receiving a positive test result as opposed to a physiological signature of the virus. Thus, wearable sensor data could facilitate the monitoring of COVID-19 prevalence, but not yet replace SARS-CoV-2 testing.

Keywords: wearable sensor; test; test results; sensor data; test result

Journal Title: PLOS ONE
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.