LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

A Comparison Between 6-Point Dixon Mri and Mr Spectroscopy to Quantify Muscle fat in the Thigh of Subjects with Sarcopenia

Photo by iamjadedestiny from unsplash

BackgroundChanges in muscle fat composition as for example observed in sarcopenia, affect physical performance and muscular function, like strength and power.ObjectivesThe purpose of this study was to compare 6-point Dixon… Click to show full abstract

BackgroundChanges in muscle fat composition as for example observed in sarcopenia, affect physical performance and muscular function, like strength and power.ObjectivesThe purpose of this study was to compare 6-point Dixon magnetic resonance imaging and multi-echo magnetic resonance spectroscopy sequences to quantify muscle fat.Setting, participants and measurementsTwo groups were recruited (G1: 23 healthy young men (28 ± 4 years), G2: 56 men with sarcopenia (80 ± 5 years)). Proton density fat fraction was measured with a 6-point product and a 6-point prototype Dixon sequence in the left thigh muscle and with a highspeed multi-echo T2*-corrected H1 magnetic resonance spectroscopy sequence within the semitendinosus muscle of the left thigh. To evaluate the comparability among the different methods, Bland-Altman and linear regression analyses of the proton density fat fraction results were performed.ResultsMean differences ± 1.96 * standard deviation between spectroscopy and 6pt Dixon sequences were 1.9 ± 3.3% and 1.5 ± 3.6% for the product and prototype sequences, respectively. High correlations were measured between the proton density fat fraction results of the 6-point Dixon sequences and spectroscopy (R = 0.95 for the product sequence and R = 0.97 for the prototype sequence).ConclusionsDixon imaging and spectroscopy sequences show comparable accuracy for fat measurements in the thigh. Spectroscopy is a local measurement, whereas Dixon sequences provide maps of the fat distribution. The high correlations of the 6-point Dixon sequences with spectroscopy support their clinical use. They provide higher spatial resolution than spectroscopy, but are not suitable for a more complicated spectral analysis to separate extra- and intramyocellular lipids.

Keywords: point dixon; spectroscopy; muscle fat

Journal Title: The Journal of Frailty & Aging
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.