Pressure measurement characteristics of a micro‐transducer and balloon catheters

Photo by florianklauer from unsplash

Respiratory pressure responses to cervical magnetic stimulation are important measurements in monitoring the mechanical function of the respiratory muscles. Pressures can be measured using balloon catheters or a catheter containing… Click to show full abstract

Respiratory pressure responses to cervical magnetic stimulation are important measurements in monitoring the mechanical function of the respiratory muscles. Pressures can be measured using balloon catheters or a catheter containing integrated micro‐transducers. However, no research has provided a comprehensive analysis of their pressure measurement characteristics. Accordingly, the aim of this study was to provide a comparative analysis of these characteristics in two separate experiments: (1) in vitro with a reference pressure transducer following a controlled pressurization; and (2) in vivo following cervical magnetic stimulations. In vitro the micro‐transducer catheter recorded pressure amplitudes and areas which were in closer agreement to the reference pressure transducer than the balloon catheter. In vivo there was a main effect for stimulation power and catheter for esophageal (Pes), gastric (Pga), and transdiaphragmatic (Pdi) pressure amplitudes (p < 0.001) with the micro‐transducer catheter recording larger pressure amplitudes. There was a main effect of stimulation power (p < 0.001) and no main effect of catheter for esophageal (p = 0.481), gastric (p = 0.923), and transdiaphragmatic (p = 0.964) pressure areas. At 100% stimulator power agreement between catheters for Pdi amplitude (bias =6.9 cmH2O and LOA −0.61 to 14.27 cmH2O) and pressure areas (bias = −0.05 cmH2O·s and LOA −1.22 to 1.11 cmH2O·s) were assessed. At 100% stimulator power, and compared to the balloon catheters, the micro‐transducer catheter displayed a shorter 10–90% rise time, contraction time, latency, and half‐relaxation time, alongside greater maximal rates of change in pressure for esophageal, gastric, and transdiaphragmatic pressure amplitudes (p < 0.05). These results suggest that caution is warranted if comparing pressure amplitude results utilizing different catheter systems, or if micro‐transducers are used in clinical settings while applying balloon catheter‐derived normative values. However, pressure areas could be used as an alternative point of comparison between catheter systems.

Keywords: micro transducer; catheter; balloon catheters; pressure

Journal Title: Physiological Reports
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.