LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Comparison of automated vs. manual measurement to estimate fetal weight in isolated polyhydramnios

Photo from wikipedia

Abstract Objective To understand the impact of the measurement method to predict actual birthweight in pregnancies complicated with isolated polyhydramnios in the third trimester. Methods A prospective study was conducted… Click to show full abstract

Abstract Objective To understand the impact of the measurement method to predict actual birthweight in pregnancies complicated with isolated polyhydramnios in the third trimester. Methods A prospective study was conducted with 60 pregnant women between the 37th and 40th weeks of gestation. Routine biometric measurements were obtained by two-dimensional (2D) ultrasonography. When a satisfactory image was obtained, the image was frozen to get two measurements. First, calipers were placed to get the manual measurement. Then automated measurement was captured by the ultrasonography machine in the same image. The fetal weight was estimated by using the Hadlock II formula. Results The mean difference was found to be 0.03, −0.77, −0.02 and 0.17 for biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC) and femur length (FL), respectively. Pearson’s correlation coefficient between automated and manual estimated fetal weights (EFWs) and the actual birthweight was 0.919 and 0.796, respectively. The mean difference between actual and manual EFW measurement values was 46.16 ± 363.81 g (range between −745 g and 685 g) (P = 0.330). Also, the mean difference between actual and automated EFW measurement values was found to be 31.98 ± 218.65 g (range between −378 g and 742 g) (P = 0.262). The Bland-Altman test results have shown that, 666 g lower or 759 g higher values were obtained when the measurement was performed manually. On the other hand, EFW results were 396 g lower or 460 g higher than the actual birthweight with automated measurement tools. Conclusion The accuracy rate of fetal weight estimation with ultrasonography is high for both automated and manual measurements. Automated tools have a higher success to predict the EFW.

Keywords: fetal weight; manual measurement; measurement; automated manual; isolated polyhydramnios

Journal Title: Journal of Perinatal Medicine
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.