LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

[Functional results of spectral correction of vision].

Photo from wikipedia

PURPOSE To study the data of monocular and binocular multifocal electroretinogram (mfERG), flash visual evoked potential (f-VEP), spatial contrast sensitivity (SCS) with and without yellow filters in healthy elderly people.… Click to show full abstract

PURPOSE To study the data of monocular and binocular multifocal electroretinogram (mfERG), flash visual evoked potential (f-VEP), spatial contrast sensitivity (SCS) with and without yellow filters in healthy elderly people. MATERIAL AND METHODS The study included 16 people (8 male and 8 female) with average age of 51.63±4.7 years. Their visual acuity was 0.5±0.35 without correction and 1.0 with correction. For spectral correction, we used Y1 color filters (CF) (analogue of SN60AT) from the «Lornet-M vision spectral correction kit» set with 80% light transmission and wave cut-off of 460 nm. Patients had mfERG recordings performed monocularly and binocularly, f-VEP monocularly, and their spatial contrast sensitivity (SCS) was measured (Astroinform SPE, Russia). The data acquired before and after applying CF was compared. RESULTS The data of SCS with light filter was slightly higher at medium and high spatial frequencies (SF): for the right eye on medium SF of 43.8 and 41.8 dB (p≤0.735), 41.5 and 39.8 dB (p≤0.061) for the left eye. The increase of mfERG P1 latency monocularly after application of CF in the R1 ring area was 3.0 ms (40.8-43.8ms) for the right eye (p≤0.05) and 0.9 ms for the left eye (43.7-44.5ms) (p≤0.326). The trend remained for simultaneous mfERG. CONCLUSION The influence of yellow filters on spectral vision correction can be manifested in inconsistency of SCS, f-VEP, monocular and binocular mfERG readings. Statistically significant differences in healthy individuals of 5th-6th age decades manifest as elongation of the latency of mfERG peaks.

Keywords: correction; spectral correction; vision; mferg; functional results; eye

Journal Title: Vestnik oftalmologii
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.