LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

BI-RADS 4 breast lesions: could multi-mode ultrasound be helpful for their diagnosis?

Photo by sebastiancoman from unsplash

Background The malignant probability of Breast Imaging Reporting and Data System (BI-RADS) 4 breast lesions is 3-94%, which is a very large span, and thus leads to a high rate… Click to show full abstract

Background The malignant probability of Breast Imaging Reporting and Data System (BI-RADS) 4 breast lesions is 3-94%, which is a very large span, and thus leads to a high rate of unnecessary biopsy. Therefore, the differential diagnosis of benign and malignant BI-RADS 4 breast lesions has become extremely important. Thus, in this paper, we investigated the diagnostic value of conventional ultrasonography (US), contrast-enhanced ultrasound (CEUS) and shear wave elastography (SWE) for BI-RADS 4 breast lesions, and tried to figure out a multi-mode ultrasonic method for them. Methods From March 2016 to May 2017, 118 breast lesions that were categorized as BI-RADS 4 lesions by US were studied with CEUS and SWE. All the lesions were confirmed by pathology via surgery or vacuum-assisted biopsy. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of US, CEUS and SWE were analyzed. Then the diagnostic efficacies of US, CEUS, SWE and the combination of these modalities were compared. Logistic regression analysis was performed to identify the independent risk factors. A multi-mode method to evaluate BI-RADS 4 lesions based on the logistic regression was developed. Results Of the 118 BI-RADS 4 lesions, 74 lesions (62.7%) were benign and 44 lesions (37.3%) were malignant. The diagnostic sensitivity and specificity for US, US + CEUS, US + SWE, US + CEUS + SWE were 88.6% and 75.7%, 86.4% and 94.6%, 88.6% and 90.5%, 97.7% and 93.2%, respectively. The area under the ROC curve (AUC) of US + SWE + CEUS was significantly higher than that of US (P<0.0001), US + CEUS (P=0.020), but there was no significant difference between the AUC of US + SWE + CEUS and the AUC of US + SWE. Conclusions US + CEUS + SWE and US + SWE could significantly improve the diagnostic efficiency and accuracy of US in the diagnosis of BI-RADS 4 breast lesions.

Keywords: ceus swe; rads breast; breast lesions; multi mode

Journal Title: Gland surgery
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.