LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Determination of five positive control drugs in hERG external solution (buffer) by LC-MS/MS to support in vitro hERG assay as recommended by ICH S7B.

Photo from wikipedia

ICH S7B recommends screening for hERG channel block using patch clamp recordings to assess a drug's proarrhythmic risk. Block of the hERG channel has been associated with clinical QTC prolongation… Click to show full abstract

ICH S7B recommends screening for hERG channel block using patch clamp recordings to assess a drug's proarrhythmic risk. Block of the hERG channel has been associated with clinical QTC prolongation as well as the rare, but potentially fatal ventricular tachyarrhythmia Torsade de Pointes (TdP). During recording, drug concentrations perfused to the cells can deviate from nominal concentrations due to molecule-specific properties (such as non-specific binding), thereby introducing error when assessing drug potency. To account for this potential source of error, both the original ICH S7B and the newly released ICH E14/S7B Q&As guidelines call for verifying drug solutions' concentrations. Dofetilide, cisapride, terfenadine, sotalol and E-4031 are hERG blockers commonly used as positive controls to illustrate hERG assay sensitivity. The first four compounds are also clinical drugs associated with high TdP risk; therefore, their safety margins may be useful comparators to better understand an investigational product's TdP risk. Having analytical methods to quantify these five compounds in the hERG external solution that will be used for patch clamp recordings is important from a regulatory science research perspective. However, a literature search revealed no analytical methods or stability information for these molecules in the high salt, serum-free matrix that constitutes the hERG external solution. This study was conducted to develop and validate LC-MS/MS methods to quantify these 5 molecules in hERG external solution. The bioanalytical methods for these positive controls were validated as per the FDA's bioanalytical method validation guidance along with various stabilities.

Keywords: herg external; ich s7b; external solution

Journal Title: Journal of pharmacological and toxicological methods
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.