LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Delayed Perforation after Endoscopic Detachable Snare Ligation for Colonic Diverticular Hemorrhage.

Photo by bhurnal from unsplash

A 74-year-old man was admitted to our hospital with severe hematochezia. Abdominal enhanced computed tomography (CT) demonstrated extravasation of contrast material from the descending colon. Colonoscopy revealed recent bleeding in… Click to show full abstract

A 74-year-old man was admitted to our hospital with severe hematochezia. Abdominal enhanced computed tomography (CT) demonstrated extravasation of contrast material from the descending colon. Colonoscopy revealed recent bleeding in the descending colon diverticulum. Bleeding was stopped using detachable snare ligation. Eight days later, the patient developed abdominalgia, and CT revealed free air caused by delayed perforation. The patient underwent emergency surgery. Perforation at the ligation site was detected using intraoperative colonoscopy. This report is the first to describe a case of delayed perforation after endoscopic detachable snare ligation for colonic diverticular hemorrhage.

Keywords: perforation; detachable snare; perforation endoscopic; delayed perforation; ligation; snare ligation