LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Establishment and Validation of an ICP-MS Method for Simultaneous Measurement of 24 Elemental Impurities in Ubenimex APIs According to USP/ICH guidelines

Photo by rhsupplies from unsplash

To control the potential presence of heavy metals in pharmaceuticals, the United States Pharmacopeia (USP) and International Conference on Harmonization (ICH) have put forth new requirements and guidelines. USP 232… Click to show full abstract

To control the potential presence of heavy metals in pharmaceuticals, the United States Pharmacopeia (USP) and International Conference on Harmonization (ICH) have put forth new requirements and guidelines. USP 232 and ICH Q3D specify 24 elemental impurities and their concentration limits in consideration of the permitted daily exposure (PDE) of different drug categories (oral, parenteral and inhalation). while USP 233 describes more information about sample preparation and method validation procedure. To establish and verify an ICP-MS method for the determination of 24 elemental impurities (Cd, Pb, As, Hg, Co, V, Ni, Tl, Au, Pd, Ir, Os, Ph, Ru, Se, Ag, Pt, Li, Sb, Ba, Mo, Cu, Sn, Cr) in ubenimex APIs according to USP/ICH guidelines. Samples were analyzed by ICP-MS after direct dissolution in diluted acid solution. All elements were detected in He/HEHe mode (except for Li, which was in No gas mode). The spiked recoveries were within 80-120% except Hg (79.4% at 0.5J level in HEHe mode) and Cd (121.9% at 0.5J level in HE mode). The RSD of repeatability (N = 6) for all elements were < 7.0% and intermediate precision (N = 12) were < 9.0%. The correlation coefficients of linear (R) for 24 elements were all > 0.998. The limits of detection (LOD) were < 1 ng/mL except that Ni was 1.23 ng/mL in HEHe mode. The contents of 24 elements in 3 batches of samples were significantly lower than the actual target limit of ICH, while the highest content of Pd did not exceed 10 μg/g. The established method was proved to be simple, sensitive and accurate. It successfully applied to the elemental impurity determination in 3 batches of ubenimex APIs from different manufactories. This method also provided technical guidance for determination of multiple elements in pharmaceutical products.

Keywords: icp method; impurities ubenimex; method; ubenimex apis; apis according; elemental impurities

Journal Title: Current Pharmaceutical Analysis
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.