LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Comment on Piccinini and Bergman The Measurement of Insulin Clearance. Diabetes Care 2020;43:2296–2302

Photo from wikipedia

We found interesting the review by Piccinini and Bergman (1) about the methods for assessing insulin clearance. However, some issues deserve comment. The authors claim that single-compartment description of C-peptide… Click to show full abstract

We found interesting the review by Piccinini and Bergman (1) about the methods for assessing insulin clearance. However, some issues deserve comment. The authors claim that single-compartment description of C-peptide kinetics may provide limited accuracy. We agree that twocompartment description is typically more appropriate, but the single-compartment approach proved to be acceptable in glucose tolerance tests characterized by low dynamics. Indeed, the study by Vølund et al. (2) reported that the C-peptide single-compartment model was acceptable for insulin and C-peptide infusion experiments in dogs and that C-peptide clearance was similar in the studied dogs and in humans from previous studies. Another study in humans showed that, even for the intravenous glucose tolerance test (IVGTT), the C-peptide singlecompartment model was the most appropriate choice in the case of individuals showing low dynamics patterns (3). In fact, in 4 out of 11 patients (i.e., ;40%), the coefficient of variation of the estimated model parameters was excessively high, indicating that in those cases the twocompartment model was not resolvable from the IVGTT data. In contrast, the singlecompartment model performed satisfactorily, aswas then confirmedbyBergman’s group that applied the single-compartment C-peptide model to IVGTT data in healthy females (4). Similar to the previous study (3), in a study of ours (5) (reference 30 in the review [1]), C-peptide single-compartment description was necessary to avoid extremely high coefficients of variation for the estimated model parameters. Thus, the single-compartment approach was the most appropriate strategy. Of note, in the review (1), use of piecewise polynomials for description of insulin secretion rate is listed as a further limitation of the model in reference 30. However, unlike several other models, that of reference 30 was validated against direct measurements from the hepatic catheterization technique, and validation was satisfactory. The review (1) also fails to report a widely used method to assess wholebody insulin clearance, that is, the ratio between the area under the curve (AUC) of the insulin secretion rate and that of plasma insulin concentration. This method may be somewhat inaccurate if plasma insulin has not returned to the basal value at the end of the glucose tolerance test. However, this limitation should be overcome by proper adjustment, as suggested for instance in study of Shah et al. (6), i.e., by using the following formula: (AUCISR/ AUCINS) – VINS 3 (INSFIN – INSINIT)/AUCINS, where ISR is insulin secretion rate, INS is plasma insulin, FIN is the final time of the test, INIT is the initial time (typically, timeof the fasting condition), and VINS represents the insulin distribution volume, usually set to 0.14 L/kg. Finally, we noticed that the study by Sherwin et al. (7) wasmentioned (reference 15 in the review) but not really presented. Toour knowledge, that studywas the first accurate model for also assessing insulin clearance (among other variables); thus, a brief description of that study should be interesting, at least from a historical point of view.

Keywords: insulin; model; single compartment; insulin clearance

Journal Title: Diabetes Care
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.