OBJECTIVE To evaluate the feasibility of using a wearable eye-tracker when assessing patients with prolonged disorders of consciousness using the Coma Recovery Scale Revised (CRS-R), focusing on technical challenges. DESIGN… Click to show full abstract
OBJECTIVE To evaluate the feasibility of using a wearable eye-tracker when assessing patients with prolonged disorders of consciousness using the Coma Recovery Scale Revised (CRS-R), focusing on technical challenges. DESIGN A methodological investigation with descriptive and analytical elements. SUBJECTS Four patients with prolonged disorders of consciousness were recruited from the rehabilitation clinic of a regional rehabilitation unit. METHODS A selection of subtests in the CRS-R were performed while recording eye movements with a wearable eye-tracker. RESULTS No major adverse reactions were observed, suggesting likely patient acceptability. Calibration was not always possible. However, distinct eye movements were discernible from the recorded data even without calibration, and analysis of these produced results with the potential to support clinical assessment. CONCLUSION Eye tracking was feasible during clinical assessment for this patient group. Recording eye movement responses in these easily fatigued patients has the potential to add sensitivity for detection of conscious responses and to complement clinical examination. Further study is merited. Current hardware and software limitations can be overcome with manual data processing and analysis; however, significant developments in automizing data processing will be required for broader clinical application.
               