LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Effect of expiratory flow limitation on ventilation/perfusion mismatch and perioperative lung function during pneumoperitoneum and Trendelenburg position.

Photo from wikipedia

BACKGROUND Laparoscopic surgery and Trendelenburg position may affect the respiratory function and alter the gas exchange. Further the reduction of the lung volumes may contribute to the development of expiratory… Click to show full abstract

BACKGROUND Laparoscopic surgery and Trendelenburg position may affect the respiratory function and alter the gas exchange. Further the reduction of the lung volumes may contribute to the development of expiratory flow limitation (EFL). The latter is associated with an increased risk of postoperative pulmonary complications. Our aim was to investigate the incidence of EFL and to evaluate its effect on pulmonary function and intraoperative V/Q mismatch. METHODS This is a prospective study on patients undergoing elective laparoscopic gynecological surgery. We evaluated respiratory mechanics, V/Q mismatch and presence of EFL after anesthesia induction, during pneumoperitoneum and Trendelenburg position and at the end of surgery. Intraoperative gas exchange and hemodynamic were also recorded. Clinical data were collected until 7 days after surgery to evaluate the onset of pulmonary postoperative complications (PPCs). RESULTS Among the 66 patients enrolled, 25/66 (38%) exhibited EFL during surgery, of whom 10/66 (15%) after anesthesia induction, and the remaining 15 patients after pneumoperitoneum and Trendelenburg position. Median PEEP able to reverse flow limitation was 7 [7-10] cmH2O after anesthesia induction and 9 [8-15] cmH2O after pneumoperitoneum and Trendelenburg position. Patients with EFL had significantly higher shunt (17 [2-25] vs. 9 [1-19]; P=0.05), low V̇/Q̇ (27 [20-70] vs. 15 [10-22]; P=0.05) and high V̇/Q̇ (10 [7-14] vs. 6 [4-7]; P=0.024). At the end of surgery, only high V/Q was significantly higher in EFL patients. Further, they exhibited higher incidence of postoperative pulmonary complication (48% (12/25) vs. 15% (6/41), P=0.005), hypoxemia and hypercapnia (80% [20/25] vs. 32% [13/41]; P<0.001). CONCLUSIONS Expiratory flow limitation is a common phenomenon during gynecological laparoscopic surgery associated with worsen gas exchange, increased V/Q mismatch and altered lung mechanics. Our study showed that patients experiencing EFL during surgery showed a higher risk for PPCs.

Keywords: trendelenburg position; surgery; pneumoperitoneum trendelenburg; flow limitation

Journal Title: Minerva anestesiologica
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.