LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Improving the metric of surgical freedom in the laboratory based on a novel concept of volume.

Photo from wikipedia

BACKGROUND In laboratory-based neuroanatomical studies, surgical freedom, the most important metric of instrument maneuverability, has been based on Heron's formula. Inaccuracies and limitations hinder this study design's applicability. A new… Click to show full abstract

BACKGROUND In laboratory-based neuroanatomical studies, surgical freedom, the most important metric of instrument maneuverability, has been based on Heron's formula. Inaccuracies and limitations hinder this study design's applicability. A new methodology, volume of surgical freedom (VSF), may produce a more realistic qualitative and quantitative representation of a surgical corridor. METHODS Overall, 297 data set measurements assessing surgical freedom were completed for cadaveric brain neurosurgical approach dissections. Heron's formula and VSF were calculated specifically to different surgical anatomical targets. Quantitative accuracy and the results of an analysis of human error were compared. RESULTS Heron's formula for irregularly shaped surgical corridors resulted in overestimation of the respective areas (minimum overestimation 31.3%). In 92% (188/204) of data sets reviewed for influence of offset, areas calculated on the basis of measured data points were larger than areas calculated on the basis of the translated best-fit plane points (mean [SD] overestimation of 2.14% [2.62%]). Variability in the probe length attributable to human error was small (mean [SD] calculated probe length 190.26 mm [5.57 mm]). CONCLUSIONS VSF is an innovative concept that can develop a model of a surgical corridor producing better assessment and prediction of the ability to maneuver and manipulate surgical instruments. VSF corrects for deficits in Heron's method by generating the correct area for an irregular shape using the shoelace formula, adjusting the data points to account for offset, and attempting to correct for human error. VSF produces 3-dimensional models and, therefore, is a preferable standard for assessing surgical freedom.

Keywords: surgical freedom; laboratory based; volume; freedom; concept

Journal Title: Journal of neurosurgical sciences
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.