Increasing tourniquet number has no effect on amikacin concentration within the radiocarpal joint in horses undergoing intravenous regional limb perfusion.

Photo from wikipedia

OBJECTIVE To determine whether IV regional limb perfusion (IVRLP) performed in the cephalic vein with a wide rubber tourniquet (WRT) applied proximal and distal to the carpus results in a… Click to show full abstract

OBJECTIVE To determine whether IV regional limb perfusion (IVRLP) performed in the cephalic vein with a wide rubber tourniquet (WRT) applied proximal and distal to the carpus results in a higher peak concentration (Cmax) of amikacin in the radiocarpal joint (RCJ), compared with the Cmax for IVRLP using a single WRT proximal to the carpus. Animals 7 healthy adult horses. Procedures Horses underwent IVRLP using standing sedation with 2 g of amikacin sulfate diluted to 60 mL by use of saline (0.9% NaCl) solution in the cephalic vein with 2 different tourniquet techniques; proximal WRT (P) and proximal and distal WRT (PD). Synovial fluid was collected from the RCJ at 5, 10, 15, 20, 25, and 30 minutes after IVRLP. Tourniquets were removed after the 30-minute sample was collected. Blood samples from the jugular vein were collected at 5, 10, 15, 20, 25, 29, and 31 minutes after IVRLP. Amikacin concentration was quantified by a fluorescence polarization immunoassay. Median peak concentration (Cmax) of amikacin and time to maximum drug concentration (Tmax) within the RCJ were determined. Results Median peak concentration in the RCJ was 1331.4 μg/mL with technique P and 683.1 μg/mL with technique PD. Median Tmax occurred at 30 minutes with technique P and 25 minutes with technique PD. No significant (Cmax, P = 0.18; Tmax, P = 0.6) difference in amikacin Cmax or Tmax between techniques was detected. Clinical Relevance Placement of 2 WRTs offers no advantage to a single proximal WRT when performing IVRLP to deliver maximal amikacin concentrations to the RCJ using IVRLP.

Keywords: radiocarpal joint; limb perfusion; regional limb; concentration; amikacin concentration

Journal Title: American journal of veterinary research
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.